The peel strength of adhesive products refers to The maximum force required for peeling the contact surface per unit width, which reflects the adhesive strength of the tape., Ltd., Ltd. on the adhesive product viscosity tester used in the laboratory of colleges and universities. Rolling machines are widely used in quality inspection agencies, packaging plants, tape factories and other units., a domestic professional manufacturer of pharmaceutical packaging materials testing equipment, provides research exchanges and internships for researchers from various universities,

scientific research institutions, and large and medium enterprises. The pharmacy major is to cultivate advanced science with basic theories, basic knowledge and experimental skills of pharmacy, capable of engaging in identification, drug design, general pharmaceutical preparations and clinical rational use of drugs in the fields of drug production, inspection, circulation, use, and research and development

The discipline of technical talent., Ltd.Jinan Sanquan Zhongshi Experimental Instrument Co. The laboratory requested the development of several special testing instruments for adhesive products. Adhesive products initial adhesion tester for colleges and universities laboratories 2. They are: 180° peel strength tester BLJ-C, initial tack tester CNY-1, holding force tester CNY-2A, adhesive tape Rolling machine YGJ-S. has developed a batch of testing equipment to promote the development of my country’s medical industry. Adhesive product initial tack tester for colleges and universities laboratory 1. The initial adhesion tester CNY-1 adopts the design of three-station rolling ball method, which greatly improves the test efficiency.

Observe and pcr tube and plate how the ink layer of the sample is peeled off to determine and analyze the bonding fastness of the ink layer. Looking for 180° peel strength tester, initial tack tester CNY-1, and lasting tack tester CNY -2A, adhesive tape rolling machine YGJ-S, please call Jinan Sanquan Zhongshi Experimental Instrument Co. It is a testing equipment developed and produced by Jinan Sanquan Zhongshi Experimental Instrument Co.
https://www.mingjibio.com/product/pcr-series/
1. At this temperature, cell Laboratory Consumables and life activities are almost completely stopped. If the laboratory funds allow, a high-quality phase contrast microscope with a camera system can be configured to photograph and record the situation of cells at any time, which is of great help to the development of scientific research work.

Therefore, it is different from other general experimental work. This environment also needs to be clean and dust-free.8 to 7. (5) The refrigerator cell culture room must be equipped with an ordinary refrigerator or a freezer, and the refrigerator preferably has a low temperature refrigerator (-20 ℃). Prevent frostbite during use. Sterile operation area (1) Sterile operation room: It is only limited to the area of ​​cell culture and other aseptic operations.,

it should be filtered and sterilized on a sterile operating table. In addition, most animal cells need to survive and grow in a slightly alkaline environment, with a pH of 7. (8) The items that the sterilizer directly or indirectly contact with the cells need to be disinfected and sterilized. Special equipment For more efficient, accurate and in-depth research on cell science, qualified (local tyrants) laboratories can add some special, advanced and sophisticated equipment and instruments, such as multifunctional enzyme-linked immunoassay analyzer,

fluorescence Microscope, flow cytometer, cell expansion system (bioreactor), etc. Recognized by scientific researchers is the gas-jacketed carbon dioxide incubator equipped with infrared sensors. 2. The cell culture laboratory should be able to perform six aspects of work: aseptic operation, incubation, preparation, cleaning, disinfection and sterilization treatment, and storage. Even so, sometimes the temporarily needed items or fragile utensils still need to be sterilized by the cell culture laboratory. It is better for each department to be installed in each connected room, especially the sterile operation room can be set separately; if they are all placed in a large laboratory, the sterile operation area and the cleaning, disinfection and sterilization area should be located at both ends. The size should be appropriate, and the top should not be too high (not more than 2.

https://www.mingjibio.com/
In addition, the resistivity value will change with the ionization constant of water, so it will be affected by the temperature of the water. Soluble organic matter: lignin, tannin, humic acid, endotoxin, RNA degrading enzymes, pesticides. are often used to supplement the important parameters of water quality. At present, the most common pure water standards in the world are the following:

International Organization for Standardization (ISO), American Society of Clinical Pathology (CAP) test-grade water standards, American Society for Testing and Materials Experiments (ASTM), International Clinical Test Standards Committee (NCCLS), American Pharmaceutical Association (USP), etc.2MΩ. , Chloroform, environmental hormone substances, surfactants, organic solvents.248MΩ.1μs/cm.

This value is usually called resistivity or specific resistance in water quality analysis, and its unit is expressed in MΩ. These two parameters are the most commonly used parameters indicating the purity of water. Microparticles: rust, colloids, suspended solids, solid particles. Minimalist operation, extreme results, and ultimate experience. For example, the resistance value of ultrapure water at 25°C is 18. It is pre-purified by ion exchange, RO membrane or distillation, and then purified by nuclear-level ion exchange purification. It can be made by a single weakly basic anion exchange resin, reverse osmosis or a single distillation.

and the Plastic Micro Tubes and content of these components determine the taste of the water. Ultrapure water is suitable for a variety of precision analysis experiments, such as high-performance liquid chromatography (HPLC), ion chromatography (IC) and ion trapping-mass spectrometry (ICP-MS). Therefore, the water purity standard is usually comprehensively described and graded by one or several of the above parameters.cm. Because the centers of positive and negative charges are inconsistent, they belong to polar molecules. Ultra-pure water with few heat sources is suitable for biological applications such as eukaryotic cell culture. In the vicinity of 25℃, when the temperature rises by 1℃, its resistance value will drop by 0. Usually the resistivity of ultrapure water can reach 18. Ultra-pure water.

https://www.mingjibio.com/product/centrifuge-tube/


Every day, there are more than 1,200 VWR resident personnel worldwide serving you in various leading pharmaceutical companies, biological fields, educational institutions, industries and public institutions in the world! Global reach, local support Global coverage, local support More than 1,200 resident personnel worldwide VWR on-site service development Four service types 1..5 billion, a million-level product range covering many countries and regions around the world, a professional team of more than 10,200 employees, VWRWe Enable Science. VWR Catalyst is specifically designed to fulfill your wishes. Instrument equipment service asset management and equipment accuracy and compliance technical support services • pipette manufacturers VEM equipment management system • Installation • Calibration • Verification

• Preventive repair and maintenance • Certification • Temperature mapping • Maintenance management • Technical service contract • Equipment asset tracking • Customer service center support • Service contract management • Equipment transfer Your Solution Starts Here With many years of technical service experience, we can help you achieve your business goals as soon as possible. VWRCATALYST can help you better complete theoretical tests, improve product quality, and reach your scientific achievements as soon as possible. Scientific research support services Personnel with advanced scientific education and scientific and technical experience • Testing standards • Cell bank management •

Compound management • Cell culture • Research plan creation and Decomposition • Open laboratory management • DNA/RNA extraction • Tissue homogenate 4. Consumables products, well-calibrated instruments and equipment to ensure the best performance.

We can formulate a detailed service project plan according to your goals and needs.. Operational support services of laboratories and product support professionals have greatly improved the efficiency of laboratories and production • Sample management • Biosafety cabinet cleaning • Dry ice replenishment • Cylinder gas management • Autoclave • Glassware cleaning • Safety-related services • Solution configuration (medium, buffer, mobile phase) 3. We understand your Science We understand you VWRCATALYST-make your laboratory operations and production operations more efficient and competitive behind-the-scenes work team

https://www.mingjibio.com/product/serological-pipette/



Do not cut and pull the tissue repeatedly, causing tissue compression. 4. Positive expression of cytoplasm and cell membrane, for example, EMA can show membranous and diffuse cytoplasmic positive reactions; CD30 antibody can show both membrane and cytoplasmic spot positive reactions. The antigens we detect are diverse. At this time, a few drops of ethanol can be appropriately added to the water. Soak the detergent powder for 30 minutes, rinse, and dry. With the extension of fixed time, the detection intensity of tissue antigen will gradually decrease. 1)

Poly-L-Lysine (poly-L-lysine) 1.0ml cryo tube, 0. Wash in PBS for 5 minutes. d The room temperature is too low: below 15 degrees, it should be placed in a 37 degree incubator for 30-60 minutes, or a 4 degree refrigerator overnight. Simple formulation method: Add 1 g NaH2PO4, 15. 1. Wash 2 times in PBS for 5 minutes each time (if necessary, apply 0. The service items include: scientific and clinical grade adenovirus, lentivirus, adeno-associated virus (AAV) packaging, plasmid vector construction, TALEN gene. Wash with PBS 2-3 times for 5 minutes each. 5.0-8. (The optimal temperature is 92-95 ° C) (3) Enzymatic digestion: the precautions for this antigen repair: 1) The tissue cannot be dried. Especially during shooting, do n’t use high magnification lens for a while, and low magnification lens for a while, switch the objective lens back and forth.

Wash 3 times in PBS for 2 minutes each. The pH of the antigen retrieval solution is very important. Not suitable for long-term preservation of tissue specimens.5mol / L EDTA buffer solution (ph8. Pure acetone II, about 5 seconds. Common physical methods include simple heating, microwave processing, and high-pressure heating. For frozen sections, formaldehyde fixation is sometimes better than frozen acetone; but for different tissues and antigens, different fixative solutions can be used. Immunohistochemical staining

The S-P immunohistochemical staining kit uses a biotin-labeled secondary antibody and a streptavidin-linked peroxidase and substrate pigment mixture to determine antigens in cells and tissues. Generally at room temperature 20-28 degrees c DAB color development time is too long or the concentration is too high

https://www.mingjibio.com/product/cryo-tube/
The failures that may occur in the laboratory ultrapure water machine during use are as follows: Fault 1: The pump of the ultrapure water machine does not start, resulting in inability to make water. The first step: observe whether the alarm indicator on the panel system of the ultrapure water machine will flicker. Yes. Possible cause of failure: low water pressure / abnormal low pressure switch / clogged activated carbon filter. no. Possible cause:

The high-voltage switch is damaged. Fault two: The laboratory ultrapure water machine system has been making water. Possible cause: High pressure switch or check valve failure. Fault three: The water production and water full conversion of the laboratory ultrapure water machine system is too frequent. Possible cause: The pressure bucket switch of the ultrapure water machine is not turned on, and water cannot be stored.

Fault four: The water output of the laboratory products manufacturers is too small. Possible causes of failure: insufficient raw water pressure, blocked PP filter element or reverse osmosis membrane. Fault five: Leakage of the pump head Possible cause: Blockage of the PP filter element or activated carbon filter element / aging of the rubber pad of the pump head or blockage of scale / blockage of wastewater ratio. Fault 6: The pump is running normally but water cannot be generated. Possible cause: The RO membrane is blocked or the waterway is blocked or the pump loses pressure. Seven: The panel water indicator is on and the water cannot be generated. Possible cause: Check whether the pump has 24VDC output to the pump. If yes, the pump is broken or blocked; if no, check whether the line is normal. Fault eight: The power indicator of the booting system does not light up and does not work.

Possible cause: Check the fuse is abnormal or the power switch fails. The choice of laboratory ultrapure water machine, Shanghai Hetai is undoubtedly the first choice. Shanghai Hetai Medium Pilot Series pure water machine / ultrapure water system is an economical choice of primary pure water for daily laboratory, which can meet the routine production process water and experiments. Roomware cleaning water requirements can be used as the water inlet for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.

https://www.mingjibio.com/